1、Design basis

乐陵

Design Standard for Steel Structures GB50017-2017Steel Structure Design Manual, China Construction Industry Press, January 2004

乐陵

乐陵Code for Construction and Acceptance of Steel Structures (GB50205-2020)

乐陵British Code for Design of Steel Structures (BS5950)

乐陵

乐陵2、Design load

Load includes structural self weight, wind turbine constant load, live load, snow load, wind load, etc. The structural calculation adopts the ultimate stress method, therefore, the load value is larger than usual. The surface load is calculated based on the distribution coefficient and applied to the platform according to the line load. The wind load is calculated based on the wind vibration coefficient, body shape coefficient, and basic wind pressure to calculate the wind pressure values on four surfaces, which are then converted into line loads and applied to the columns. Auxiliary components such as stair handrails are applied to the stairs according to uniformly distributed loads.

乐陵1. Constant load

乐陵

乐陵The self weight of the steel structure is automatically calculated by the program, and the node weight is considered based on the self weight of the structure multiplied by 1.3. The weight and fluid load of the radiator are applied by external forces.

乐陵

Platform constant load: 0.50kN/m2

乐陵

乐陵2. Live load

乐陵

乐陵Live load of the platform for loading: 2.5kN/m2

乐陵3. Snow load

乐陵

According to relevant design data, the snow pressure can be basically calculated as 0.4N/m2.

乐陵

乐陵4. Wind load

乐陵Calculate according to the maximum value.

乐陵

乐陵Basic wind pressure: 0.35kN/m2, height variation coefficient of 1.8, wind vibration coefficient: 1.5, ground roughness category: Class A

乐陵

乐陵Class.

乐陵Is the standard value of wind load, is the wind vibration coefficient at height Z, is the shape coefficient of wind load, and is the coefficient of wind pressure height variation.

乐陵When the standard value of wind load is less than 0.75kpa, calculate based on 0.75 kPa and multiply by 1.4 times the safety factor. Namely

乐陵5. Temperature load

乐陵

乐陵The temperature difference is relatively small. The structural form is single, and the linear expansion of steel has a relatively small impact on the overall performance of the structure, which can be ignored.

6 Earthquake loads

乐陵According to the seismic analysis design method: small earthquakes do not damage, medium earthquakes are repairable, and large earthquakes do not collapse. Small earthquake analysis can be divided into: bottom shear force method, response spectrum analysis, and elastic time history analysis. Medium earthquake analysis is calculated by multiplying small earthquake analysis by amplification factor.

乐陵

乐陵Seismic fortification intensity: 8 degrees

乐陵

乐陵Design basic seismic acceleration peak value: 0.3g

Construction site category: II site

Design grouping: Second group

乐陵

乐陵Damping ratio: 0.05

乐陵

乐陵This structure adopts MIADS software for overall modeling and analysis. During modeling, beam elements are mainly used for each structure. In order to facilitate loading, plate elements are established at the structural platform. Consolidation is used as the boundary condition at the bottom of each column, and constraints are applied at the connection between the column and the original structure according to the actual situation. The structure includes upright column, cross brace, slant support and upper and lower platform steel structure.

乐陵Load sub factors and load combinations:

乐陵

乐陵Number

乐陵load

乐陵Partial    coefficient remarks

乐陵Partial    coefficient remarks

1

乐陵

dead load

乐陵

1.3

乐陵

2

乐陵

乐陵Dead load, when   it has a restraining effect on uplift and   overturning

1.0

乐陵

乐陵3

乐陵Dead load, when   acting together with wind load and live load

乐陵

1.2

乐陵

乐陵4

乐陵

Live load

乐陵

乐陵1.6

乐陵

5

乐陵Live load, when   combined with wind load

乐陵

1.2

乐陵6

Wind load

乐陵

乐陵1.4

7

乐陵

When combined   with wind load and live load

乐陵

1.2

乐陵

乐陵3、 Radiator calculation

乐陵

1. Material parameters

Aluminum alloy adopts 6005-T1, with tensile strength and yield strength equivalent to 6063-T5, tensile strength ≥ 150Mpa, yield stress ≥ 110 Mpa. According to the performance table of aluminum alloy, it is found that 6063-T5 has a tensile strength of 185Mpa, yield stress of 145 Mpa, and fatigue strength of 90MPa.

乐陵2. Working condition analysis

The calculation of radiators can be divided into 1. lifting ondition,

乐陵3. operating condition (operating condition is divided into

乐陵

乐陵4.support and lifting point participate in force simultaneously.

乐陵

5.support bears gravity, while lifting point bears horizontal force.

乐陵

乐陵6.support does not bear any force, that is, when the overall structure is subjected to uneven settlement, there is a suspension at the bottom)

乐陵To ensure its stability, it is recommended that the foundation treatment should be pre compressed and settlement assessment should be carried out during the overall installation.

2.1 Hoisting conditions

乐陵

At this point, the radiator is only considered for its own weight due to the lack of fluid injection, and is lifted and installed through a side lifting point. Because no other accessories were installed during modeling, in order to estimate the weight more accurately, its self weight coefficient was defined as 1.3.

乐陵The radiator structure consists of 1, frame 2, support beam 3, heat exchange tube 4, tube plate, and other ancillary structures. As the heat exchange tube and support beam are fixed together through a corrugated plate, it can be considered that the heat exchange tube participates in the structural stress, which leads to strain and stress generation.

乐陵The overall structural model is

乐陵

乐陵Radiator structural model

乐陵

The overall deformation of the radiator during the lifting process

乐陵

乐陵

乐陵Stress cloud diagram of radiator during lifting process

乐陵

乐陵From its displacement cloud map, it can be seen that its overall deformation is 1.2mm, and the maximum stress is 15MPa

乐陵

乐陵

Stress cloud map of heat sink

乐陵

乐陵

 

Displacement cloud map of heat sink

乐陵

From its displacement cloud map, it can be seen that its overall deformation is 1mm and the maximum stress is 2MPa. Through calculation, it can be seen that horizontal lifting has little effect on the heat dissipation fins, and its deformation and stress are far less than the standard requirements.

乐陵

乐陵The vertical lifting situation is as follows:

乐陵

乐陵

乐陵Vertical lifting stress cloud map